CPD-G220(E)
5
DIAGNOSIS
Failre
Horizontal / Vertical Deflection failure,
(Included S-cap)
ABL protector
HV failure
Aging / Self Test
Out of scan range
Power LED
Amber
Off
(1.5 sec)
(0.5 sec)
Amber
Off
(0.5 sec)
(1.5 sec)
Amber
Off
(0.5 sec)
(0.5 sec)
Amber
Off
Green
Off
(0.5 sec)
(0.5 sec)
(0.5 sec)
(0.5 sec)
Green (OSD indication)
Aging Mode (Video Aging)
:
During Power Save, press MENU button for longer than 2 second.
Monitor Information and RGB bar :
During Power Save, push CONT+ button for longer than 2 second.
ALL White
:
During Power Save, push CONT- button for longer than 2 second.