— 14 —
CPD-E440
4-2. PRINTED WIRING BOARD AND
SCHEMATIC DIAGRAM INFORMATION
All capacitors are in µF unless otherwise noted. pF : µµF 50WV or less
are not indicated except for electrolytics and tantalums.
are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specifi ed.
All resistors are in ohms. k
Ω=1000Ω, MΩ=1000kΩ
Indication of resistance, which does not have one for rating electrical
power, is as follows:
power, is as follows:
Pitch : 5mm
Rating
electrical
power
:
1
/
4
W
1
/
4
W in resistance,
1
/
10
W and
1
/
8
W in chip resistance.
: nonfl ammable resistor.
: fusible resistor.
: internal component.
: panel designation and adjustment for repair.
: earth ground
: earth-chassis
All variable and adjustable resistors have characteristic curve B, unless
otherwise noted.
otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10M
Ω digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production tolerances.
All voltages are in V.
S : Measurement impossibillity.
: B+line.
: B-line (Actual measured value may be different).
: signal path (RF).
4-1. CIRCUIT BOARDS LOCATION
RESISTOR
: RN METAL FILM
: RC SOLID
: FPRD NONFLAMMABLE CARBON
: FUSE NONFLAMMABLE FUSIBLE
: RW NONFLAMMABLE WIREWOUND
: RS NONFLAMMABLE METAL OXIDE
: RB NONFLAMMABLE CEMENT
:
: RN METAL FILM
: RC SOLID
: FPRD NONFLAMMABLE CARBON
: FUSE NONFLAMMABLE FUSIBLE
: RW NONFLAMMABLE WIREWOUND
: RS NONFLAMMABLE METAL OXIDE
: RB NONFLAMMABLE CEMENT
:
ADJUSTMENT RESISTOR
COIL
: LF-8L MICRO INDUCTOR
: LF-8L MICRO INDUCTOR
The components identifi ed by shading and
!
symbol are critical for safety. Replace
only with part number specifi ed.
The symbol
indicates a fast operating fuse and is displayed on the component
side of the board. Replace only with fuse of the same rating as marked.
Les composants identifi es per un trame et une marque
!
sont critiques pour la
securite. Ne les remplacer que par une piece portant le numero specifi e.
Le symbole
indique une fusible a action rapide. Doit etre remplace par une
fusible de meme yaleur, comme maque.
Circled numbers are waveform references.
The components identifi ed by X in this basic schematic diagram
have been carefully factory-selected for each set in order to
satisfy regulations regarding X-ray radiation. Should replacement be
necessary, replace only with the value originally used.
have been carefully factory-selected for each set in order to
satisfy regulations regarding X-ray radiation. Should replacement be
necessary, replace only with the value originally used.
When replacing components identifi ed by Y, make the necessary
adjustments as indicated. If the results do not meet the specifi ed
value, change the component identifi ed by X and repeat the
adjustment until the specifi ed value is achieved.
adjustments as indicated. If the results do not meet the specifi ed
value, change the component identifi ed by X and repeat the
adjustment until the specifi ed value is achieved.
(Refer to Safety Related Adjusments Section 2)
When replacing the parts listed in the table below, it is important to
perform the related adjustments.
perform the related adjustments.
CAPACITOR
: TA TANTALUM
: PS STYROL
: PP POLYPROPYLENE
: PT MYLAR
: MPS METALIZED POLYESTER
: MPP METALIZED POLYPROPYLENE
: ALB BIPOLAR
: ALT HIGH TEMPERATURE
: ALR HIGH RIPPLE
: TA TANTALUM
: PS STYROL
: PP POLYPROPYLENE
: PT MYLAR
: MPS METALIZED POLYESTER
: MPP METALIZED POLYPROPYLENE
: ALB BIPOLAR
: ALT HIGH TEMPERATURE
: ALR HIGH RIPPLE
SECTION 4: DIAGRAMS
Part Replaced ( )
HV ADJ
RV501
Part Replaced ( )
D Board
IC501,C532, C534, C539, C553,
C554, C555, C556, C558, C561,
R540, R541, R542, R544, R564,
R567, R568, RV501, T501, (FBT)
C554, C555, C556, C558, C561,
R540, R541, R542, R544, R564,
R567, R568, RV501, T501, (FBT)
HV Regulator
Circuit Check
Circuit Check
D Board
IC607, IC901, D515, D517, C540,
C542, C544, C951, R510, R543,
R547, R549, R552, R595, T501
(FBT)
C542, C544, C951, R510, R543,
R547, R549, R552, R595, T501
(FBT)
HV Protector
Circuit Check
Circuit Check
D Board
IC605, IC607, IC901, C535, C541,
R545, R546, R548, R550, R596,
R934, T501 (FBT)
R545, R546, R548, R550, R596,
R934, T501 (FBT)
Beam Current
Protector Circuit
Check
Protector Circuit
Check