CPD-E230 - Sony Monitor Service Manual (repair manual). Page 18

Read Sony CPD-E230 Service Manual online

CPD-E230(E)
3-3
7. If necessary, the 3-6 procedures.
8. Change the "CONV SW" to 6. then set the following registers to 0.
                 "YBH_T_HI", "TBH_T_LO"
                 "YBH_B_HI", "YBH_B_LO"
                 "VSTAT_T_HI", "VSTAT_T_LO"
                 "VSTAT_B_HI""VSTAT_B_HI"
9. Adjust the H Static and V Static with the register "HSTAT_HI" and
"VSTAT_HI". (These registers should be within the limit between -40
and +40.)
10. Insert to TLH correction board and correct H. TILT.
11. Adjust  XCV with the XCV volume.
12 Adjust YCH with the YCH volume.
13 Adjust  V. TILT with the TLV-VR.
14. If  necessary, repeat the 1-13 procedures to get the most suitable conver-
gence pattern.
15. Paint lock TLH corection board, neck assy 4, 6 pole magnet and XCV
volume.
Purity Mg
4-pole Mg
6-pole Mg
XCV
YCH
H-Trap
TLH
TLV
TB, Pin VI
4 Pole
6 Pole
[ Neck Assy's Zero Position ]
Purity
B
R
R
B
R
B
B
R
R
B
B
XCV
YCH
TLV
TLH 
B
A
A
0.20 mm
B
MODE
All mode
0.24 mm
White Balance Adjustmen  Specification
(1) 9300K
Part of shadow line
for the right figure.
(2) 5000K
Part of shadow line
for the right figure.
Convergence Specification
VR
x = 0.283
y = 0.298
0.005
0.005
x = 0.346
y = 0.359
0.005
0.005
Page of 69
Display