*The parts above (     ~     ) are necessary for DAS adjustment.
IBM AT Computer
 
as a Jig
1-690-391-21
1
A-1500-819-A
Interface Unit
2
3
D-sub
(9 Pin [female])
mini Din
(8Pin)
4 Pin
3-702-691-01
Connector Attachment
3
To BUS CONNECTOR
4 Pin
4 Pin
1
CRT
Neck Ass’y
A Board
Purity
Magnet
XCV VR
6-pole
Mg
TLH Plate
DY
4-pole
Mg
H-Trp VR
TLV VR
YCV VR
SECTION  4
ADJUSTMENTS
4-1
Connect the communication cable of the connector located on the D board on the monitor. Run the service software and then follow
the instructions.
Allow a 30 minute warm-up period prior to making the following adjustments:
4-1. Landing Rough Adjustment
1.
Display the all white pattern.
2.
Adjust the contrast to maximum value.
3.
Display the plain green pattern.
4.
Slide the DY back and roughly adjust the plain green
pattern with the purity magnet so that it is centered on
the screen.
5.
Moving the DY forward, adjust so that an entire
screen becomes pure green.
6.
Adjust the tilt of DY and tighten lightly with a clamp.
4-2. Landing Fine Adjustment
1.
Place the monitor in the Helmholtz coil.
2.
Set TLH plate to zero position.
3.
Display plain green pattern.
4.
Degauss CRT face and iron parts with degauss
equipment or hand-degausser.
5.
Perform auto degauss.
6.
Attach a wobbling coil to the specified position of
CRT neck.
7.
Put the sensor of landing checker to CRT face.
8.
Adjust purity, DY position and DY tilt.
9.
Tighten DY screw.
10. Perform auto degauss.
11. Adjust top and bottom pin by pitching DY up and
down with two wedges so that [a] is equal to [b].
1.
Display crosshatch pattern with green lines and black
field.
2.
Adjust V. Key (=H. Trapezoid) with H-Trp VR so that
[a] is equal to [b].
3.
Change “CONV_OFF_NDX” to “7”.
12. If the corner landing is out of specification, use a disk
magnet for the landing correction.
13. If disk magnets were used, perform an auto degauss.
14. Remove the wobbling coil and sensor.
15. Fix the purity magnet on DY with white paint.
4-3. Convergence Rough Adjustment
1.
Enter the white crosshatch signal.
2.
Roughly adjust the horizontal (H.STAT) and vertical
(V.STAT) convergence at four-pole magnet.
3.
Roughly adjust HMC and VMC at six-pole magnet.
4-4. Convergence and V. Key (H. Trp) Fine Adjustment
Page of 43
Display