CPD-E210 - Sony Monitor Service Manual (repair manual). Page 2

Read Sony CPD-E210 Service Manual online

— 2 —
CPD-E210
POWER MANAGEMENT
The power saving mode complies with the VESA Display Power Management Signaling standard.  Each
state of power management shall be activated by the host computer terminating the appropriate sync
signals.  Blanking the video must precede termination of the sync signals.  The elapsed time counter
shall also be controlled by the host computer.  Reactivation of the monitor shall be accomplished from
the host computer by re-establishing the normal sync signal.
Status
Area of Failure
LED Indication
1 Failure 1
HV or +B
Amber (0.5 second)/Off (0.5 second)
2 Failure 2
Amber (1.5 second)/Off (0.5 second)
3 Failure 3
ABL
Amber (0.5 second)/Off (1.5 second)
4 Aging/Self Test
Amber (0.5 second)/Off (0.5 second)/
Green (0.5 second)/Off (0.5 second)
H Stop or V Stop
TIMING SPECIFICATION
SELF DIAGNOSIS FUNCTION
When a failure occurs, the STANDBY/TIMER lamp will flash a set number of times to indicate the
possible cause of the problem.  If there is more than one error, the lamp will identify the first of the
problem areas.
Power consumption
Screen
Horizontal
Vertical
Power
Recovery  time
 indicator
mode
(video)
sync signal
sync signal consumption
1
Normal operation
active
yes
yes
< 120 W
--
Green
2
Standby (1st mode)
blank
no
yes
< 15 W
Approx. 5 sec.
Green and Orange
Alternate
3
Suspend (2nd mode)
blank
yes
no
< 15 W
Approx. 5 sec.
Green and Orange
Alternate
4
Active-off (3rd mode)
blank
no
no
< 3 W
Approx. 10 sec.
Orange
5
Power-off
--
--
--
0 W
--
Off
Primary Mode
MODE
1
2
3
4
5
6
7
8
Resolution (H x V)
640 X 480
800 X 600
832 x624
1024 X 768
1024 X 768
720 X 400
640 X 480
1280 X 1024
Dot Clock (MHz)
25.175
56.250
57.283
78.750
94.500
28.322
36.000
135.000
HORIZONTAL
Hor. Freq. (kHz)
31.469
53.674
49.725
60.023
68.677
31.469
43.269
79.976
H-Total
31.778
18.631
20.111
16.660
14.561
31.777
23.111
12.504
H-Blanking
6.356
4.409
5.586
3.657
3.725
6.355
5.333
3.022
H-Front Porch
0.636
0.569
0.559
0.203
0.508
0.636
1.556
0.119
H-Sync.
3.813
1.138
1.117
1.219
1.016
3.813
1.556
1.067
H-Back Porch
1.907
2.702
3.910
2.235
2.201
1.907
2.222
1.837
H-Active
25.422
14.222
14.524
13.003
10.836
25.422
17.778
9.481
(µsec)
VERTICAL
Ver. Freq. (Hz)
59.940
85.061
74.550
75.029
84.997
70.087
85.008
75.025
V-Total
525
631
667
800
808
449
509
1066
V-Blanking
45
31
43
32
40
49
29
42
V-Front Porch
10
1
1
1
1
12
1
1
V-Sync.
2
3
3
3
3
2
3
3
V-Back Porch
33
27
39
28
36
35
25
38
V-Active
480
600
624
768
768
400
480
1024
(lines)
SYNC.
Int 
(G)
NO NO NO NO NO NO NO NO 
Ext (H/V)/Polarity
YES -/-
NO +/+
YES -/-
YES +/+
YES +/+
YES -/+
YES -/-
YES +/+
Ext 
(CS)/Polarity
NO
NO NO NO NO NO NO NO 
Int/Non Int
NON INT
NON INT
NON INT
NON INT
NON INT
NON INT
NON INT
NON INT
TIMING SPECIFICATION
Page of 40
Display