CPD-210EST, CPD-210GS - Sony Monitor Service Manual (repair manual). Page 13

Read Sony CPD-210EST / CPD-210GS Service Manual online

CPD-210GS/210EST
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling up it in
the direction of the arrow 
c
.
• HOW  TO  HANDLE  AN  ANODE-CAP
1
Don’t hurt the surface of anode-caps with shartp shaped material!
2
Don’t press the rubber hardly not to hurt inside of anode-caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don’t turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or hurt the rubber.
a
b
Anode Button
c
• REMOVAL  OF  ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT,
after removing the anode.
• REMOVING  PROCEDURES
1
Turn up one side of the rubber cap in
the direction indicated by the arrow 
a
.
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow 
b
.
2-4. PICTURE TUBE  REMOVAL
2-2
1
2
     Two screws
(+BVTP 4 x 16)
     A board
     Neck assy
     Four screws
(Tapping screw 5)
     Deflection yoke
     Picture tube
     Anode cap
Cushion
Bottom cover
(D board)
     Stand assy
3
Claw
6
Claw
4
5
     Two screws
(+BVTT 4 x 8)
7
13
12
8
9
     Picture tube 
shield
11
10
Connector
(2pin)
CN506
CN501
CN603
GND
GND
CN307
Page of 39