CPD-110EST, CPD-110GS - Sony Monitor Service Manual (repair manual). Page 13

Read Sony CPD-110EST / CPD-110GS Service Manual online

CPD-110GS/110EST
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling up it in
the direction of the arrow 
c
.
• HOW  TO  HANDLE  AN  ANODE-CAP
1
Don’t hurt the surface of anode-caps with shartp shaped material!
2
Don’t press the rubber hardly not to hurt inside of anode-caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don’t turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or hurt the rubber.
a
b
Anode Button
c
• REMOVAL  OF  ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT,
after removing the anode.
• REMOVING  PROCEDURES
1
Turn up one side of the rubber cap in
the direction indicated by the arrow 
a
.
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow 
b
.
2-4. PICTURE TUBE  REMOVAL
2-2
     
Demagnetic coil
12
13
     
Tension spring
2
  
 
  
A board
GND
GND
CN506
GND
GND
CN308
CN307
Two 
degaussing
coil holders
14
CN501
CN603
Two screws
(+BVTP 4 x 16)
5
     
Stand assy
4
3 Claw
Bottom cover
(D board)
7
6 Claw
Cushion
Two degaussing
coil holders
15
1
  
 
  
Anode cap
     
Picture tube
11
     
Deflection yoke
9
     
Neck assy
8
     
Four screws
(Tapping screw 5)
10
Connector
(2pin)
Page of 39