DVP-S9000ES - Sony DVD Service Manual (repair manual). Page 116

Read Sony DVP-S9000ES Service Manual online

7-4
10. Checking S Video Output S-C
<Purpose>
This checks whether the S-C satisfies the NTSC Standard.  If it is
not correct, the colors will be too dark or light.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
S VIDEO OUT (S-C) connector
(75 
 terminated)
Instrument
Oscilloscope
Specification
A = 286 ± 30 mVp-p (NTSC)
A = 300 ± 100 mVp-p (PAL)
Checking method:
1) In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2) Confirm that the S-C burst is “A”.
Figure 7-10
A
8. Checking RGB Output G (AEP, UK Model)
<Purpose>
This checks RGB output G.  If it is incorrect, pictures will not be
displayed correctly in spite of connection to the TV with an EURO
AV connecting cord.
Mode
In test mode,
Push 
[0]
 for Syscon Diagnosis and
push 
[8]
 for Video and push 
[8]
 and
[ENTER]
 for Euro TV Check and
push 
[NEXT]
 twice for RGB out
Signal
Color bars
Test point
EURO AV 1 (RGB)-TV connector
pin qa (75 
Ω 
terminated)
Instrument
Oscilloscope
Specification
700 ± 50 mVp-p
Checking method:
1) Confirm that the G level is 700 ± 50 mVp-p.
Figure 7-8
9. Checking RGB Output B (AEP, UK Model)
<Purpose>
This checks RGB output B.  If it is incorrect, pictures will not be
displayed correctly in spite of connection to the TV with an EURO
AV connecting cord.
Mode
In test mode,
Push 
[0]
 for Syscon Diagnosis and
push 
[8]
 for Video and push 
[8]
 and
[ENTER]
 for Euro TV Check and
push 
[NEXT]
 twice for RGB out
Signal
Color bars
Test point
EURO AV 1 (RGB)-TV connector
pin 7 (75 
Ω 
terminated)
Instrument
Oscilloscope
Specification
700 ± 50 mVp-p
Checking method:
1) Confirm that the B level is 700 ± 50 mVp-p.
Figure 7-9
700 ± 50 mVp-p
700 ± 50 mVp-p
Page of 127
Display