6-15
2-3-4. Communication Monitoring Display
The communication state is monitored and displayed while the
key name on the main unit and the remote commander is displayed.
When the communication to the System Controller failed, VIDEO
CD, DVD, and CD segments turn on.
Communication error display (at no key input)
Communication error display (at code display without input of
the remote commander)
2-3-5. FLD Anode Test Display and SHUTTLE Click
Operation Test
2-3-5-1. Transition Keys in Self Check Mode
• DVD MENU 
 RIGHT, LEFT 
 [TEST ANODE] 
RETURN
• SHUTTLE on the main unit and the remote commander during
Anode Test display
2-3-5-2. Operation and Display
Only the first segment of each grid of FLD is lit, and the segments
of each grid are switched over sequentially by entering the RIGHT
or LEFT on the remote commander. The segments are switched to
1-2-3 direction at the input of RIGHT on the remote commander,
while they are switched reversely such as 3-2-1 direction at the
input of LEFT. This test checks whether each segment makes in-
dication individually.
Display at the start of Anode Test
                
↓      
(Input in RIGHT direction)