DVP-NS9100ES - Sony DVD Service Manual (repair manual). Page 22

Read Sony DVP-NS9100ES Service Manual online

22
DVP-NS9100ES
4. FL Tube Grid and Segment Check
First, a grid lights up one after another, and when grid 16 lights up,
all grids light up.
Next, all grids go off, and segments are displayed while changing
the patterns.
A way of this display is repeated.
(The interval of grid lighting is 0.2 second, and that of segment
lighting is 0.4 second.)
If the
x
button is pressed, the test proceeds to the following SIRCS
reception check.
5. SIRCS Reception Check
Upon start of the SIRCS reception check, “SIRCS CHECK” is
displayed on the FL tube.
Once the SIRCS key code is received, the test proceeds to the
following Key check.
If the
x
button is pressed as a cancel processing of the SIRCS
reception check, the test proceeds to the following Key check.
FL tube GRID check
The 18th SEG of each GRID on
GRID16 on
ALL OFF
The 1st SEG of each GRID on
The 2nd SEG of each GRID on
GRID1 on
(0.2 sec interval)
(0.2 sec interval)
(0.2 sec interval)
(0.4 sec interval)
(0.4 sec interval)
(0.4 sec interval)
(0.4 sec interval)
(ALL GRIDs light up)
(0.2 sec interval)
GRID2 on
Wait  for SIRCS code receiving
(Once the SIRCS code is 
received, the check finishes.)
Cancel processing
(Press the  
x
  button)
SIRCS reception check
SIRCS reception check finish
DISPLAY  SECTION
DISPLAY  TEST  MODE
Execute the Self Check Mode along the following flow.
1. Entering the Display Test Mode
The Display Test mode starts if either of the following conditions is
satisfied.
Condition 1:
With the SELF_CHECK (pin oj) of the IF CON (IC404) on the
MAIN board kept “low”, turn the power on.
Condition 2:
While pressing the
x
key on the set when the set is in standby
state, press the [RETURN]  t  [DISPLAY]  key on the remote
commander and the mode transits to the Self Check mode.
When the Self Check mode started, “TEST START” is displayed
on the FL tube for 2 seconds and then the Self Check proceeds to
the IF CON information display.
2. Releasing the Display Test Mode
To release the Self Check mode, disconnect the AC plug.
3. IF CON Information Display
When enter this mode, it displays as follows.
If the
x
button is pressed, the test proceeds to the following FL
tube GRID and SEGMENT check.
I/F CON information
FL tube grid and segment check 
SIRCS reception check
Key check
Jog and LED check
START
FINISH
All segments turn on
Model type display
Destination display
i.LINK ID display
Version display
ROM creation date display
Page of 127
Display