6-4-1.  EXECUTING  MIRROR  TIME  ADJUSTMENT
In order to execute mirror time adjustment, the following standard
procedures must be followed.
(1)
In standby mode, press 
[TOP MENU]
[CLEAR]
,
I/
1
but-
tons to enter Remocon Diagnosis Mode.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History Check
4. Version information
5. Video Level Adjustment
Model Name : DPX-xxxx_xx
IF-con : Ver. x.xxx (xxxx)
Syscon : Ver. x.xxx
(2)
Select “2. Drive Manual Operation”.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time Adjust
0. Return to Top Menu
(3)
Select “5. MIRR time Adjust”.
MIRR time adjustment Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time
[Open] Tray open [Close] tray close
[0] Return to previous menu
(4)
Select “5. Default set MIRR time”.
(5)
Select “3. Threshold”.
(6)
Confirm the number. If it is 75, go to next step. If it is any
other value, return to step 4.
MIRR time adjustment Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:
3. Threshold: 75
4. Save to EEPROM:
5. Default set MIRR time
[Open] Tray open [Close] tray close
[0] Return to previous menu
(7)
Push
A
button to eject tray.
(8)
Insert Test Disc HLX-504 into tray.
(9)
Push
A
button to close tray.
(10) Push “2. DVD MIRR time Check”.
(11) Wait for HEX number to display.
(12) Confirm the number, if XX is 28 – 70, proceed with next
step. If no, return to 7.
MIRR time adjustment Menu
1. CD MIRR time Check:
2. DVD MIRR time Check: xx xx
3. Thereshold:
4. Save to EEPROM:
5. Default set MIRR time
[Open] tray open [close] tray close
[0] Return to previous menu
(13) Push “4. Save to EEPROM”.
(14) Confirm the same values are displayed. If it is not same, re-
turn to step 7.
MIRR time adjustment Menu
1. CD MIRR time Check:
2. DVD MIRR time Check: XX XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time
[Open] Tray open [close] tray close
[0] Return to previous menu
(15) Push
A
button to eject tray.
(16) Take out HLX-504 and insert Test Disc YEDS-18 into tray.
(17) Push
A
button to close tray.
(18) Push “1. CD MIRR time check”.
(19) Wait for HEX number to display.