Read Sony DVP-K88P / DVP-K88PM Service Manual online
7-1
DVP-K88P
/K88PM
This section describes procedures and instructions necessary for
adjusting electrical circuits in this unit.
adjusting electrical circuits in this unit.
Instruments required:
(1) Color monitor TV
(2) Oscilloscope 1 or 2 phenomena, band width over 100 MHz, with
(1) Color monitor TV
(2) Oscilloscope 1 or 2 phenomena, band width over 100 MHz, with
delay mode
(3) Frequency counter (over 8 digits)
(4) Digital multimeter
(5) Standard commander (RMT-D181A/P)
(6) DVD reference disc
(4) Digital multimeter
(5) Standard commander (RMT-D181A/P)
(6) DVD reference disc
HLX-501 (J-6090-071-A) (dual layer) (NTSC)
HLX-503 (J-6090-069-A) (single layer) (NTSC)
HLX-504 (J-6090-088-A) (single layer) (NTSC)
HLX-505 (J-6090-089-A) (dual layer) (NTSC)
HLX-503 (J-6090-069-A) (single layer) (NTSC)
HLX-504 (J-6090-088-A) (single layer) (NTSC)
HLX-505 (J-6090-089-A) (dual layer) (NTSC)
7-1. POWER SUPPLY OUTPUT VOLTAGE
CHECK
Mode
Except standby
Instrument
Digital multimeter
EVER +5 V Check
Test point
Test point
CN201 pin 4
Specification
5.0 ± 0.3 Vdc
SW +3.3 V Check
Test point
Test point
CN201 pin 5
Specification
3.35 ± 0.2 Vdc
SW+5 V Check
Test point
Test point
CN201 pin 6
Specification
5.0 Vdc
SW +8 V Check
Test point
Test point
CN201 pin 1
Specification
8.0 ± 0.5 Vdc
EVER +11 V Check
Test point
Test point
CN201 pin 3
Specification
11.0 Vdc
EVER –10 V Check
Test point
Test point
CN201 pin q;
Specification
–10.0 Vdc
Checking method:
(1) Confirm that each voltage satisfies the specification.
(1) Confirm that each voltage satisfies the specification.
Caution!
Please do not touch any electrical parts at primary circuit to avoid
electrical shock.
Please do not touch any electrical parts at primary circuit to avoid
electrical shock.
+0.5
–1.0
+1.0
–0.5
+0.2
–0.3
SECTION 7
ELECTRICAL ADJUSTMENT
Click on the first or last page to see other DVP-K88P / DVP-K88PM service manuals if exist.