4-31
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
4-7-3. Focus Brush Pattern Check(Focus Brush Pattern)
Equipment
• Personal Computer
• Finished Inspection JIG (AC 100 V only)
• Lens Adjustment Program (ActuatorChecker.exe)
1. Preparations
1)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2)
Start up of “ActuatorChecker.exe”.
3)
Click 
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Checking Method
1)
Click the 
[Focus Pattern]
.
Fig.4-7-13
2)
The Serial window appears. Input the lens serial number.
Note:
When 
[OK]
 is clicked without inputting the serial number, the date executed is displayed on the completion window of each
item.
Fig.4-7-14
3)
The message “Move FOCUS to Near position. Then push [ENTER].” is displayed on the pop-up window.
Set the focus to the near position and press down the ENTER key.
Fig.4-7-15