SAL85F14Z - Sony Digital Camera Service Manual (repair manual). Page 60

Read Sony SAL85F14Z Service Manual online

4-16
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
4-2-2. Aperture Diameter Adjustment
Equipment
• Luminance Box
• Camera DSLR-A100
• AE Master Lens
• Compact Flash (CF) Card (For image saving)
• Personal Computer (PC) (Color Calculator 2 installed)
• Adhesive bond (B-10)
1. Preparations
1)
Separate all lens elements in front of the 
aperture blade unit 
(subject side). (Refer to Section 2-1-1.)
2)
Remove the adhesive bond fixing the 
aperture unit holding spring 
(3 areas).
3)
Confirm the aperture error of checking lens. (Refer to Section 4-2-1.)
2. Adjustment Method
1)
Turn the aperture unit holding ring to change aperture diameter of the 
aperture blade unit
.
Fig.4-2-8
2)
Repeat check and adjustment until the aperture error is within the standard.
3)
After adjustment, apply the adhesive bond (B-10), and fix the 
aperture unit holding spring
.
Fig.4-2-9
4)
Assemble the lens completely, perform “4-2-1. Aperture Diameter Check”.
Note:
Repeat “4-2-2. Aperture Diameter Adjustment” and “4-2-1. Aperture Diameter Check”,until the aperture error meets the
specification.
Adjustment that use this hole
Turn to right : Aperture open
Turn to left  : Aperture close
Aperture Unit Holding Ring
Aperture Unit Holding Spring
Apply the adhesive bond (B-10) (width of 5 to 10mm)
Aperture Unit Holding Spring
Ver. 1.3  2007.10
The changed portions from
Ver. 1.2 are shown in blue.