Adhesive bond (B-10): J-6082-612-A
1.
Set the focus to the near position.
2.
Assemble the MF detection brush block in the arrow direction as shown in the figure.
Note:
Be careful not to bend the leads of brush.
3.
Move the focus ring by 10mm in the infinity direction.
4.
Slide the MF detection brush block and align the screw hole of MF detection brush block with the front holding barrel.
5.
Tighten two screws and apply the adhesive bond (B-10) to the indicated portions of screw heads.
6.
Adjust the position of flexible PWB, aligning the positioning hole of flexible PWB, and solder it.
7.
Route the harness as shown in the figure and solder it.
Assemble the MF detection
brush block in the arrow direction
Soldering
(Harness)
Harness
(Green)
Harness
(Black)
Apply the adhesive
bond (B-10)
Soldering
(Flexible PWB)
Move the focus ring by 10mm
in the infinity direction
Slide the MF detection brush
block and align the screw hole
of MF detection brush block