SAL70200G - Sony Digital Camera Service Manual (repair manual). Page 113

Read Sony SAL70200G Service Manual online

5-47
SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
6)
When the Lens Starting Circuit Check finishes normally, the DMF Ring Rotation Detect Switch Check is started, set the focus to near
position and press down the ENTER key.
Fig.5-10-5
7)
When the DMF Ring Rotation Detect SW Check finishes normally, the Focus Adjustment Point Check is started, set the focus to
infinity position and press down the ENTER key.
Fig.5-10-6
8)
When the Focus Adjustment Point Check finishes normally, the Focus Pattern Check is started, set the focus to near position at about
5 sec.
Fig.5-10-7
9)
Next, set the focus to infinity position at about 5 sec.
Fig.5-10-8
10) When the Focus Pattern Check finishes normally, the Zoom Adjustment Point Check is started, set the zoom to WIDE position and
press down the ENTER key.
Fig.5-10-9
11) When the Zoom Adjustment Point Check finishes normally, the Zoom Pattern Check is started, set the zoom to TELE position and
press down the ENTER key.
Fig.5-10-10
12) Next, set the zoom to WIDE position at about 10 sec at a stretch.
Fig.5-10-11
Page of 127