SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
[How to select ActuatorChecker with HALF COMPLETION JIG in half completion inspection]
Note 1: 
The connection in the half completion inspection should be completed.
Note 2: 
The lens adjustment program (ActuatorChecker) Ver3.08 or later is needed.
1. Start up "ActuatorChecker"
2. Click the  Set up  button.
3. When "Half" of SAL70200G is selected, the AD TYPE appears.
4. Select Type I or II (It is changed by click) with reference to the below.
Description for AD TYPE
 AD TYPE: I
 Select if using the HALF COMPLETION JIG (J-6082-692-A)
 AD TYPE: II
 Select if using the modified SSM HALF COMPLETION JIG (J-6082-662-A)
5. Click the  OK  button.
*
It appears after selecting the AD TYPE: I
(HALF COMPLETION JIG (J-6082-692-A))
*
It appears after selecting the AD TYPE: II
(SSM HALF COMPLETION JIG (J-6082-
662-A))