5-46
SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
5-10. FINISHED INSPECTION (ActuatorChecker)
5-10-1.
Finished inspection (ActuatorChecker)
Equipment
Personal Computer
Finished Inspection JIG (AC100 V only)
Lens Adjustment Program (ActuatorChecker)
1. Preparations
1)
 Connected to equipment with checking lens. (Refer to Fig. 5-1-25 of Section 5-1-3.)
2)
Start up of “ActuatorChecker”.
3)
Click [Set up], and perform the initial setting. (Refer to Section 5-1-4.)
2. Checking Method
1)
Click [START].
Fig.5-10-1
2)
The Serial window appears. Input the lens serial number.
Note:
When [OK] is clicked without inputting the serial number, the date executed is displayed on the completion window of each item.
     Fig.5-10-2
3)
The following window appears, press down the ENTER key.
Fig.5-10-3
4)
It starts from the ROM Data inspection, and it advances to the CPU Mode Standby Current check by the automatic operation.
5)
When the CPU Mode Standby Current Check finishes normally, the Lens Stating Circuit Check is started, change AF-MF switch to
MF.
Fig.5-10-4