SAL50M28 - Sony Digital Camera Service Manual (repair manual). Page 28

Read Sony SAL50M28 Service Manual online

HELP
SAL50M28 (MACRO 2.8/50) (50mm F2.8 Macro)
HELP27
Cut the polyester tape (Black) 10 mm for 7
×100 mm, attach the polyester tape (Black) 10 mm fitting its upper side to the edge of the fixed
barrel on the mount side.
HELP28
Anti-diffusion agent (A-20): J-6082-611-A
1.
Apply the anti-diffusion agent (A-20) to the shaded area of the focus scale plate.
2.
Attach so that the scratch line of the focus scale plate and reference line of the focus ring are aligned.
Reference line
(It separates from the 
end of R 1 to 2 mm)
Fixed Barrel Unit
Apply the anti-diffusion
agent(A-20)
Reference line
Reference line
Fixed Barrel Unit
Scratch line
Focus Scale Plate
About 2 mm
Page of 65
Display