SAL500F40G - Sony Digital Camera Service Manual (repair manual). Page 9

Read Sony SAL500F40G Service Manual online

2-6
SAL500F40G (4/500 G SSM) (500mm F4 G SSM)
HELP07
1.  Solder the harnesses to the CL-32 (DC) PC board as shown in the figure.
CL-032 (DC) PC Board
CL-032 (DC) 
PC Board
Harness
(Blue)
(From Stator)
(From Connection 
 Box Block)
Harness (Yellow)
Harness
(Black)
Harness
(Red)
Harness
(Black)
HELP08
Grease (G-85): J-6082-626-A
Adhesive bond (LOCTITE)
Note:
  Use the adhesive bond (LOCTITE 460) or the equivalent.
 
Do not use the instant glue which becomes white after dried.
1.  Apply two drops of adhesive bond (LOCTITE 460) to the tip of stopper screw and tighten it to the mount.
2.  Apply the grease (G-85) the indicated portion of mount (lens A mount).
Stopper Screw
Entrance side
Inner side
Outer side
Entrance 
side
Entrance side
 Apply the grease
(G-85)
Mount 
(Lens A Mount)
(Cross section)
Mount (Lens A Mount)
Mount (Lens A Mount)
Back side of claw (3 locations)
Apply the adhesive
bond (LOCTITE 460).
HELP09
1.  Install the connection flexible (B) block with its hole facing up.
Connection Flexible (B) Block
Connection Flexible 
(B) Block
Hole
CL-032 (DC) PC Board
CL-034 (MM) PC Board
CL-032 (DC) PC Board
HELP10
Adhesive bond (B-40): J-6082-614-A
1.  Thread the flexible encoder DV and the MR connection flexible through the hole of joint tube and install the joint tube.
2.  Apply two drops of adhesive bond (B-40) to the tips of six screws and fix the joint tube with six screws.
3.  Affix two sheets of flexible substrate tape H to the indicated portion of joint tube.
4.  Affix the flexible encoder DV and the flexible connect MR to the flexible substrate tape H from the hole of joint tube.
Flexible Encoder DV
Flexible Connect MR
Joint Tube
Flexible Substrate Tape H
Apply the adhesive
bond (B-40)
Apply the adhesive
bond (B-40)
Holes
Page of 66