Read Sony SAL35F14G Service Manual online
HELP
SAL35F14G (1.4/35G) (35mm F1.4G)
HELP14
Anti-diffusion agent (A-20): J-6082-611-A
Adhesive bond (B-10):
J-6082-612-A
1.
Apply anti-diffusion agent (A-20) to the indicated portion of inner barrel.
2.
After “4-2-2. Aperture Diameter Adjustment”, apply the adhesive bond (B-10) in with of 10mm to all circumferences of portions
indicated in figure at inner barrel, aperture holding ring and aperture unit holding spring.
G7
G8
G9
G10
G10 Stopper
Inner Barrel
Aperture Unit Holding Spring
Aperture Unit Holding Spring
Aperture Holding Ring
Apply the adhesive bond (B-10)
Apply the adhesive bond (B-10)
(width of 10mm to 3 locations)
(width of 10mm to 3 locations)
3 Group Lens Block
Inner Barrel
Apply the anti-diffusion agent (A-20) to
all circumference of indicated portion.
all circumference of indicated portion.
Apply the anti-diffusion agent (A-20) to
all circumference of indicated portion.
all circumference of indicated portion.
Click on the first or last page to see other SAL35F14G service manuals if exist.