SAL1680Z - Sony Digital Camera Service Manual (repair manual). Page 92

Read Sony SAL1680Z Service Manual online

4-46
SAL1680Z (Vario-Sonnar DT 3.5-4.5/16-80 ZA) (Vario-Sonnar T
*
 DT 16-80mm F3.5-4.5 ZA)
4)
When the near position check finishes normally, the message “Move FOCUS to Infinity position. Then push [ENTER].” is displayed
on the pop-up window.
Set the focus to the infinity position and press down the ENTER key.
Fig.4-11-11
5)
When the infinity position check finishes normally, “OK” is displayed on the pop-up window, and press the ENTER key to return to
the initial window.
Fig.4-11-12
3. In case of error display in the Focus Adjustment Point
1)
When the error display and the NG display appear to the pop up window, press the ENTER key to return to the initial window, and
perform “2. Checking Method”again.
• In case of error at the near position in the Focus Adjustment Point
Fig.4-11-13
Fig.4-11-14
• In case of error at the infinity position in the Focus Adjustment Point
Fig.4-11-15
Fig.4-11-16
2)
Although the lens is positioned at the near position or the infinity position, if “NG” appears, confirm or perform the following.
• 4-11-1. Focus Brush Position Adjustment (Search Focus Adjustment Point)
• Cleaning of flexible pattern or the brush.
• Replaceing the brush.
3)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.
Page of 98
Display

Click on the first or last page to see other SAL1680Z service manuals if exist.