SAL135F18Z - Sony Digital Camera Service Manual (repair manual). Page 71

Read Sony SAL135F18Z Service Manual online

4-35
SAL135F18Z (Sonnar 1.8/135 ZA) (Sonnar T
*
 135mm F1.8 ZA)
4. In case of error display in the Focus Pattern (infinity position)
1)
When the error display and the NG display appear to the pop-up window, perform the work with caution so that setting the lens to the
infinity position can be done in more than 5 seconds and no more than 10 seconds.
• When the focus pattern error
Fig.4-8-20
Fig.4-8-21
• When the lens does not reach the infinity end infinity position seconds.
Fig.4-8-22
2)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.
Page of 79
Display

Click on the first or last page to see other SAL135F18Z service manuals if exist.