NEX-VG30, NEX-VG30E, NEX-VG30EH, NEX-VG30EM, NEX-VG30H (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 8

Read Sony NEX-VG30 / NEX-VG30E / NEX-VG30EH / NEX-VG30EM / NEX-VG30H (serv.man2) Service Manual online

1-4
NEX-VG30/VG30E/VG30EH/VG30EM/VG30H_L2
– ENGLISH –
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Turn power off and turn power on again.
E
6
1
1
1
The abnormalities in initialization of the focus 
lens and the abnormalities in initialization of 
the zoom lens occurred simultaneously.
Turn power off and turn power on again.
E
6
1
3
0
Reset position detection error on the stepper 
iris initializing
Refer to “1-7. METHOD OF COPING WITH LENS ERROR”.
E
6
2
0
0
Handshake correction function does not work 
well. (With PITCH angular velocity sensor 
output stopped.)
Turn power off and turn power on again.
E
6
2
0
1
Handshake correction function does not work 
well. (With YAW angular velocity sensor 
output stopped.)
Turn power off and turn power on again.
E
6
2
0
2
Abnormality of IC for steadyshot.
Turn power off and turn power on again.
E
6
2
0
3
IC for steadyshot and micro controller com-
munication abnormality among.
Turn power off and turn power on again.
E
6
2
0
4
Image vibration correction during handshake 
function does not work.
Turn power off and turn power on again.
E
6
2
1
0
Shift lens initializing failure.
Turn power off and turn power on again.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to “1-7. METHOD OF COPING WITH LENS ERROR”.
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to “1-7. METHOD OF COPING WITH LENS ERROR”.
E
6
2
2
0
Abnormality of thermistor.
Refer to “1-7. METHOD OF COPING WITH LENS ERROR”.
E
6
2
3
0
Abnormality of main CPU.
Turn power off and turn power on again.
E
9
1
0
1
Abnormality when flash is being charged.
Turn power off and turn power on again.
E
9
1
0
2
Abnormality of flash unit.
Turn power off and turn power on again.
E
9
1
0
3
Abnormality of flash unit Temperature 
detection.
Turn power off and turn power on again.
E
9
2
0
1
Battery current value goes over the max 
discharge current
Check the remaining battery power because this symptom maybe 
depended on the remaining battery level, and confirm whether or 
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each 
output of DC/DC converter on IC4301 of VC-1011 board with the 
AC adaptor connected DC JACK (J901). 
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing or back up the 
flash memory
Check the OneNAND of CPU (IC1301 on the VC-1011 board).
E
9
4
0
1
Internal flash memory fault
Turn power off and turn power on again.
E
9
4
0
2
BGM data error
Check the CPU (IC1301 on the VC-1011 board).
E
9
5
0
0
GPS hardware error
Turn power off and turn power on again.
E
9
6
0
0
Map area mount error
Turn power off and turn power on again.
E
9
7
0
0
Projector  hardware error
Turn power off and turn power on again.
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
1-7.  METHOD OF COPING WITH LENS ERROR
When lens error is occurred, check the following items.
Lens error codes:
・  E: 61: 30 (Reset position detection error on the stepper iris initializing)
・  E: 62: 11 (Shift lens overheating (Pitch))
・  E: 62: 12 (Shift lens overheating (Yaw))
・  E: 62: 20 (Abnormality of thermistor)
Check items:
1.  Replace the lens.
2.  Replace the VC-1011 board or IC1301 on the VC-1011 board.
3.  Check that the square wave is appeared below points.
・ BODY_VD_LENS (pin 7 of CN5201 or pin 6 of IC5201 on the MT-1003 board)
・ BODY_DATA_LENS (pin 3 of CN5201 or pin 4 of IC5203 on the MT-1003 board)
・ LENS_DATA_BODY (pin 4 of CN5201 or pin 5 of IC5202 on the MT-1003 board)
Page of 31