NEX-FS700, NEX-FS700C, NEX-FS700CK, NEX-FS700E, NEX-FS700EK, NEX-FS700J, NEX-FS700JK, NEX-FS700K, NEX-FS700U, NEX-FS700UK - Sony Digital Camera Service Manual (repair manual). Page 7

Read Sony NEX-FS700 / NEX-FS700C / NEX-FS700CK / NEX-FS700E / NEX-FS700EK / NEX-FS700J / NEX-FS700JK / NEX-FS700K / NEX-FS700U / NEX-FS700UK Service Manual online

1-3
NEX-FS700/FS700K/FS700C/FS700CK/FS700E/FS700EK/FS700J/FS700JK/FS700U/FS700UK
1-5. SELF-DIAGNOSIS FUNCTION
1-5-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis 
function starts working, and displays on the LCD screen what to do.
This function consists of two display; self-diagnosis display and service 
mode display.Details of the self-diagnosis functions are provided in the 
Instruction manual.
1-5-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the LCD 
screen shows a 4-digit display consisting of an alphabet and numbers,
which blinks at 3.2 Hz. This 5-character display indicates the “repaired 
by:”, “block” in which the problem occurred, and “detailed code”of the 
problem.
0 0
3 2
C
Repaired by:
Refer to “1-5-3. Self-diagnosis Code Table”.
Indicates the appropriate
step to be taken.
E.g.
13 ....Format the “memory card”.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
E : Corrected by service
engineer
LCD screen
C : Corrected by customer
1-5-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
0
4
0
0
Non-standard battery is used.
Use the InfoLITHIUM battery.
C
0
6
0
0
The battery pack temperature is high.
Change the battery pack or place it in a cool place.
C
1
3
0
1
Memory card is unformatted.
Memory card is broken.
Format the memory card.
Insert a new memory card.
C
1
3
0
2
Access error
Remove the power source. Reconnect it again and operate your cam-
corder again.
C
1
3
0
3
Access error (External media)
Turn power off and turn power on again.
C
1
3
0
4
Drive fault (External media)
Turn power off and turn power on again.
C
E
3
2
6
1
6
0
0
0
Difficult to adjust focus
(Cannot initialize focus)
Turn power off and turn power on again.
E
2
0
0
0
Flash memory data are rewritten.
Make flash memory data correct value. (Note 1)
E
3
1
0
0
Drive fault
Turn power off and turn power on again.
Note 1: Start the Adjust Manual in the Adjust Station and refer to the “DESTINATON DATA WRITE”.
Note 2: Functions of codes with * mark are not provided in this unit.
(                                            )
*
*
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Turn power off and turn power on again.
E
6
1
1
1
The abnormalities in initialization of the focus 
lens and the abnormalities in initialization of 
the zoom lens occurred simultaneously.
Turn power off and turn power on again.
E
6
1
3
0
Reset position detection error on the stepper 
iris initializing
Refer to [1-6. METHOD OF COPING WITH LENS ERROR].
E
6
2
0
0
Handshake correction function does not work 
well. (With PITCH angular velocity sensor 
output stopped.)
Turn power off and turn power on again.
E
6
2
0
1
Handshake correction function does not work 
well. (With YAW angular velocity sensor 
output stopped.)
Turn power off and turn power on again.
E
6
2
0
2
Abnormality of IC for steadyshot.
Turn power off and turn power on again.
E
6
2
0
3
IC for steadyshot and micro controller com-
munication abnormality among.
Turn power off and turn power on again.
E
6
2
0
4
Image vibration correction during
handshake function does not work.
Turn power off and turn power on again.
E
6
2
1
0
Shift lens initializing failure.
Turn power off and turn power on again.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to [1-6. METHOD OF COPING WITH LENS ERROR].
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to [1-6. METHOD OF COPING WITH LENS ERROR].
E
6
2
2
0
Abnormality of thermistor.
Refer to [1-6. METHOD OF COPING WITH LENS ERROR].
E
9
1
0
1
Abnormality when flash is being charged.
Turn power off and turn power on again.
E
9
1
0
2
Abnormality of flash unit.
Turn power off and turn power on again.
E
9
1
0
3
Abnormality of flash unit Temperature 
detection.
Turn power off and turn power on again.
E
9
2
0
1
Battery current value goes over the max 
discharge current
Check the remaining battery power because this symptom maybe 
depended on the remaining battery level, and confirm whether or 
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each out-
put of DC/DC converter on IC4301 of VC-650 board with the AC 
adaptor connected DC JACK (J901). 
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing or back up the 
flash memory
Check the OneNAND of CPU (IC1301 on the VC-650 board).
E
9
4
0
1
Internal flash memory fault
Turn power off and turn power on again.
E
9
4
0
2
BGM data error
Check the CPU (IC1301 on the VC-650 board).
E
9
5
0
0
GPS hardware error
Turn power off and turn power on again.
E
9
6
0
0
Map area mount error
Turn power off and turn power on again.
E
9
7
0
0
Projector  hardware error
Turn power off and turn power on again.
– ENGLISH –
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Page of 110
Display