Read Sony DSC-WX60 / DSC-WX80 (serv.man2) Service Manual online
DSC-WX60/WX80_L2
1-5
– ENGLISH –
1-6-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
1
3
0
1
The internal memory has experienced a me-
dia error.
dia error.
Turn the power off and on again.
The internal memory has experienced a for-
mat error.
mat error.
Format the internal memory.
Memory card is unformatted.
Format the memory card.
Memory card is broken.
Insert a new memory card.
Memory card type error
Insert a supported memory card.
The camera cannot read or write data on the
memory card.
memory card.
Turn the power off and on again, or taking out and inserting the memory
card several times.
card several times.
C
3
2
0
1
Trouble with hardware
Turn the power off and on again.
E
4
1
0
0
Abnormality of wireless LAN module (CP801
on the SY-1007 board) or Host CPU (IC211
on the SY-1007 board).
on the SY-1007 board) or Host CPU (IC211
on the SY-1007 board).
Replace the SY-1007 board.
E
6
1
0
0
Difficult to adjust focus
(Cannot initialize focus)
(Cannot initialize focus)
Retry turn the power on by the power switch. If it does not recover,
check the focus reset sensor of lens block (pin 6 of CN401 on the
SY-1007 board). If it is OK, check the focus motor drive IC (IC401
on the SY-1007 board).
check the focus reset sensor of lens block (pin 6 of CN401 on the
SY-1007 board). If it is OK, check the focus motor drive IC (IC401
on the SY-1007 board).
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
(Cannot initialize zoom lens.)
Retry turn the power on by the power switch. Check the zoom FG of
lens block (pin qd, qg of CN401 on the SY-1007 board) when zooming
is performed when the zoom button is operated. If it is OK, check the
zoom motor drive IC (IC401 on the SY-1007 board).
lens block (pin qd, qg of CN401 on the SY-1007 board) when zooming
is performed when the zoom button is operated. If it is OK, check the
zoom motor drive IC (IC401 on the SY-1007 board).
E
6
1
3
0
Reset position detection error on the stepper
iris initializing
iris initializing
Turn power off and turn power on again.
E
6
2
0
2
Abnormality of IC for steadyshot.
Check or replacement of the IC for steadyshot (IC401 on the SY-1007
board).
board).
E
6
2
1
0
Lens initializing failure.
Check or replacement of the IC for steadyshot (IC401 on the SY-1007
board).
board).
E
6
2
1
1
Lens overheating (PITCH).
Check the HALL element (PITCH) of optical image stabilizer (pin wg,
wj
wj
of CN401 on the SY-1007 board). If it is OK, check PITCH angular
velocity sensor (SE401 on the SY-1007 board) peripheral circuits.
E
6
2
1
2
Lens overheating (YAW).
Check the HALL element (YAW) of optical image stabilizer (pin wd,
wf
wf
of CN401 on the SY-1007 board). If it is OK, check YAW angular
velocity sensor (SE401 on the SY-1007 board) peripheral circuits.
E
6
2
2
0
Abnormality of thermistor.
Check the OIS temp sensor of optical image stabilizer (pin el of
CN401 on the SY-1007 board).
CN401 on the SY-1007 board).
E
9
1
0
0
Battery / Dry cell distinction defect
Turn power off and turn power on again.
E
9
1
0
1
Abnormality when flash is being charged.
Checking of flash unit or replacement of flash unit. (Note 1)
E
9
4
0
0
Internal memory fault
Inspect the internal memory (IC211 on the SY-1007 board).
E
9
5
0
0
GPS hardware error
Turn power off and turn power on again.
E
9
5
0
1
Acceleration sensor hardware error
Turn power off and turn power on again.
E
9
5
0
2
Electronic compass hardware error
(GPS hardware error)
(GPS hardware error)
Turn power off and turn power on again.
Note 1: After repair, be sure to perform “1-7. PROCESS AFTER FIXING FLASH ERROR”.
Note 2: Functions of codes with * mark are not provided in this unit.
Note 2: Functions of codes with * mark are not provided in this unit.
1-7. PROCESS AFTER FIXING FLASH ERROR
When “FLASH error” (Self-diagnosis Code E : 91 : 01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is changed
automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated.
automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated.
Method for Initializing the Flash Error Code
Reset Flash Error using the Flash Error Repair Tool Ver_[].[].exe.
*
*
*
Click on the first or last page to see other DSC-WX60 / DSC-WX80 (serv.man2) service manuals if exist.