Read Sony DSC-WX220 Service Manual online
DSC-WX220
4-9
4-4. LENS BLOCK
4-4-1. Removal and Installation
(1) Ornamental Ring A or Barrier Assy Replacing Method
Note: As for the figure below, this model and the shape
of the main body are different.
下図は当機種と本体の形状が異なります。
Note:
Barrier Assy
Claws
Claws
Barrier Assy
Claws
Claws
Hole
Barrier
Lever
Installation
Removal
Ornamental Ring A
Barrier Tapes
Barrier Assy
Barrier Tapes
Ornamental Ring A
Disengage the four claws and remove the Barrier Assy.
Fit the four claws while inserting the Barrier Lever into the hole and attach the Barrier Assy.
Peel off the release papers of the Barrier Tapes.
Install the Ornamental Ring A and press it lightly.
Install the Ornamental Ring A and press it lightly.
Turn on the power switch and extend the lens (TELE end).
Detach the battery.
Apply alcohol to two gaps A of the Ornamental Ring A with tweezers or a fine-tipped stick as shown below.
Turn the Ornamental Ring A clockwise and counterclockwise to detach it.
Detach the battery.
Apply alcohol to two gaps A of the Ornamental Ring A with tweezers or a fine-tipped stick as shown below.
Turn the Ornamental Ring A clockwise and counterclockwise to detach it.
Solvent
A
Tweezers