DSC-W610 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 10

Read Sony DSC-W610 (serv.man2) Service Manual online

DSC-W610_L2
1-7
1-
9
.  ORNAMENTAL RING A OR BARRIER ASSY REPLACING METHOD
1-
10
. OPTICAL STEPPING MOTOR (F1380) REPLACING METHOD
3
Peel off release papers of Barrier Tapes.
4
Install Ornamental Ring A and press it lightly.
Installation
1
Affix two Barrier Tapes to Barrier Assy.
Note: The tape must not be wrinkled.
2
With four claws fitted in position, install the Barrier Assy.
5
Remove Barrier Assy by disengaging four claws.
Ornamental Ring A
Barrier Assy
Barrier Tapes
Barrier Tape
Barrier Tape
A
Removal
1
Turn on the power switch and extend the lens.
2
Detach the battery.
3
Pour a solvent such as alcohol from two places A to the tweezers or a needle shown below into a gap of Ornamental Ring A.
4
Remove while turning the Ornamental Ring A right and left.
Solvent
Ornamental Ring A
Tweezers
Barrier Assy
Claws
Claws
Barrier Assy
Claws
Claws
Barrier
Lever
Hole
Removal
1
Remove four screws, and  remove the Rear Mirror Plate.
2
Remove one screw.
3
Remove the four soldering, and remove the Optical Stepping Motor (F1380).
1
Solder the four locations.
2
Install the Optical Stepping Motor (F1380) with one screw.
*Tightening torque = 0.049 
± 0.01N • m (0.5 ± 0.1kgf • cm)
3
Install the Rear Mirror Plate with the four screws in the order of numbers.
*Tightening torque = 0.049 
± 0.01N • m (0.5 ± 0.1kgf • cm)
Installation
Optical Stepping
Motor (F1380)
Optical Stepping
Motor (F1380)
Screw
Solders
Screw
Solders
4
1
2
3
Screw
Screw
Screw
Screw
Rear Mirror Plate
Screw
Screw
Screw
Screw
Rear Mirror Plate
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2012.05
Page of 23
Display