DSC-W580 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 5

Read Sony DSC-W580 (serv.man2) Service Manual online

DSC-W580_L2
1-3
– ENGLISH –
1-6.  PROCESS AFTER FIXING FLASH ERROR
When “FLASH error” (Self-diagnosis Code E : 91 : 01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is changed 
automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Flash error code can be initialized by the operations on the HOME screen.
Method for Initializing the Flash Error Code
Initialize 
Initializes the setting to the default setting.  
Even if you execute this function, the images are retained. 
1. MENU 
 
 (Settings) 
 
 (Main Settings) 
 [Initialize] 
 [OK] 
 
Note 
Be sure not to turn off the camera while initializing. 
1-5-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
1
3
0
1
The internal memory has experienced a me-
dia error.
Turn the power off and on again.
The internal memory has experienced a for-
mat error.
Format the internal memory.
Memory card is unformatted.
Format the memory card.
Memory card is broken.
Insert a new memory card.
Memory card type error
Insert a supported memory card.
The camera cannot read or write data on the 
memory card.
Turn the power off and on again, or taking out and inserting the memory 
card several times.
C
3
2
0
1
Trouble with hardware
Turn the power off and on again.
E
6
1
0
0
Difficult to adjust focus
(Cannot initialize focus)
Retry turn the power on by the power switch. If it does not recover, 
check the focus reset sensor of lens block (pin wk of CN401 on the 
SY-274 board). If it is OK, check the focus motor drive IC (IC401 on 
the SY-274 board).
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Retry turn the power on by the power switch. Check the zoom reset 
sensor of lens block (pin eg of CN401 on the SY-274 board) when 
zooming is performed when the zoom button is operated. If it is OK, 
check the zoom motor drive IC (IC401 on the SY-274 board).
E
6
2
0
2
Abnormality of IC for steadyshot.
Check of the IC for steadyshot (IC401 on the SY-274 board).
E
6
2
1
0
Lens initializing failure.
Check of the IC for steadyshot (IC401 on the SY-274 board).
E
6
2
2
0
Abnormality of thermistor.
Check the OIS temp sensor of optical image stabilizer (pin wa of 
CN401 on the SY-274 board).
E
6
2
1
1
Lens overheating (PITCH).
Check the HALL element (PITCH) of optical image stabilizer (pin qf, 
qh
 of CN401 on the SY-274 board). If it is OK, check PITCH angular 
velocity sensor (SE401 on the SY-274 board) peripheral circuits.
E
6
2
1
2
Lens overheating (YAW).
Check the HALL element (YAW) of optical image stabilizer (pin qd, 
qa
 of CN401 on the SY-274 board). If it is OK, check YAW angular 
velocity sensor (SE401 on the SY-274 board) peripheral circuits.
E
9
1
0
1
Abnormality when flash is being charged.
Checking of flash unit or replacement of flash unit. (Note)
E
9
4
0
0
Internal memory fault
Inspect the internal memory (IC201 on the SY-274 board).
Note: After repair, be sure to perform “1-6. PROCESS AFTER FIXING FLASH ERROR”.