DSC-W370 - Sony Digital Camera Service Manual (repair manual). Page 6

Read Sony DSC-W370 Service Manual online

DSC-W370
2-2
NOTE  FOR  REPAIR
•  Make sure that the flat cable and flexible board are not cracked of
bent at the terminal.
 Do not insert the cable insufficiently nor crookedly.
•  When remove a connector, don’t pull at wire of connector. It is pos-
sible that a wire is snapped.
•  When installing a connector, don’t press down at wire of connector.
 It is possible that a wire is snapped.
•  Do not apply excessive load to the gilded flexible board.
Cut and remove the part of gilt
which comes off at the point.
(Be careful or some
pieces of gilt may be left inside)
The charging capacitor is charged up to the maximum 310 V
potential.
There is a danger of electric shock by this high voltage
when the capacitor is handled by hand. The electric shock
is caused by the charged voltage which is kept without dis-
charging when the main power of the unit is simply turned
off. Therefore, the remaining voltage must be discharged as
described below.
Preparing the Short Jig
To preparing the short jig, a small clip is attached to each end
of a resistor of 1 kΩ /1 W (1-215-869-11).
Wrap
W
W
insulating tape fully around the leads of the resistor to
prevent electrical shock.
DISCHARGING OF THE CHARGING CAPACITOR
Wrap insulating tape.
R:1 k /1 W
(Part code: 1-215-869-11)
Strobe Unit
Note:
Note:
High-voltage cautions
High-voltage cautions
Discharging the Capacitor
Short-circuit between the two points with the
short jig about 10 seconds.
To avoid the spark with the metal plate,
wrap the short jig with the insulation tape.
Short-circuit between the two points with the
short jig about 10 seconds.
To avoid the spark with the metal plate,
wrap the short jig with the insulation tape.