DSC-W360, DSC-W560 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 14

Read Sony DSC-W360 / DSC-W560 (serv.man2) Service Manual online

DSC-W360_L2
2-2
The charging capacitor (C901) of the AF-125 flexible board is 
charged up to the maximum 315 V potential.
There is a danger of electric shock by this high voltage when the 
capacitor is handled by hand.  The electric shock is caused by the 
charged voltage which is kept without discharging when the main 
power of the unit is simply turned off.  Therefore, the remaining 
voltage must be discharged as described below.
Preparing the Short Jig
To preparing the short jig, a small clip is attached to each end of 
a resistor of 1 k
Ω /1 W (1-215-869-11).
Wrap insulating tape fully around the leads of the resistor to 
prevent electrical shock.
NOTE  FOR  REPAIR
•  Make sure that the flat cable and flexible board are not cracked 
of bent at the terminal.
  Do not insert the cable insufficiently nor crookedly.
•  When remove a connector, don’t pull at wire of connector. It is 
possible that a wire is snapped.
•  When installing a connector, don’t press down at wire of con-
nector. 
  It is possible that a wire is snapped.
•  Do not apply excessive load to the gilded flexible board.
DISCHARGING OF THE CHARGING  CAPACITOR (C901)
Note: High-voltage cautions
Discharging the Capacitor
Short-circuit between two points with the short jig 
about 10 seconds.
R:1 k
Ω/1  W  
(Part  code: 1-215-869-11)
C901
Rear Side
Front Side
AF-125 Flexible
Board
Cut and remove the part of gilt
which comes off at the point.
(Be careful or some
pieces of gilt may be left inside)
Wrap insulating tape.
Page of 30
Display