DSC-W200 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 27

Read Sony DSC-W200 (serv.man4) Service Manual online

6-25
DSC-W200_ADJ
Preparation:
1) Read the PITCH sensor (SY-178 board SE502) sensitivity writ-
ten on repair parts, and named this as S
502
.
2) Read the YAW sensor (SY-178 board SE501) sensitivity writ-
ten on repair parts, and named this as S
501
.
Fig. 6-1-21
How to read the sensitivity data of angular velocity sen-
sor
With the pins 1 and 2 of angular velocity sensor placed in the
lower position, read the data value.
Fig. 6-1-22
8.
CAMERA Adjustment 7
Perform this adjustment only when replacing the angular velocity
sensor or lens block. When the microprocessor, circuit etc. is dam-
aged, don't perform this adjustment but check the operations only.
8-1. Precaution before adjustment
Before adjustment, read the following data and record them.
When the SY-178 board is replaced, read out the data before the
replacement, and record them.
Reading out method:
1) Read out the data in Block:11, Page:61, Address:0E10, and
name this as Dp.
2) Read out the data in Block:11, Page:61, Address:0E11, and
name this as Dy.
Note: The previous data (Dp, Dy) can be read from the SY-
178 board and it can be saved in the PC as a file by
using the Automatic Adjustment Program. (See page
6-26)
8-2. Preparation when the angular velocity
sensor or the SY-178 board is replaced
Note down the sensitivity displayed on the angular velocity sensor of
the repair parts. At this time, note down also to which board it was
attached to.
Be sure to check because if attached incorrectly, the screen will vi-
brate up and down or left and right during the steady shot operations.
Precautions on the Parts Replacement
The PITCH sensor and the YAW sensor are different parts.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care as
if it dropped, the balance of oscillator will be disrupted and opera-
tions will not be performed properly.
Adjustment Block
11
Adjustment Page
61
Adjustment Address
0E10, 0E11
Note: The sensor sensitivity of SE501 and SE502 of the SY-178
board is written only repair parts.
SE501
1
2
3
4
1
2
3
4
SY-178 BOARD (SIDE A)
PITCH sensor sensitivity     S
502
YAW sensor sensitivity
    S
501
PP
YY
SE502
For the sensor sensitivity value 60
6 0
Hand Writing
1
2
4
3
Description example :