DSC-W120, DSC-W125 (serv.man3) - Sony Digital Camera Service Manual (repair manual). Page 26

Read Sony DSC-W120 / DSC-W125 (serv.man3) Service Manual online

6-25
DSC-W120/W125_ADJ
9-3. Preparation when the lens is replaced
Note down the PITCH/YAW data on the replacement lens for repair.
Adjustment Block
11
Adjustment Page
61
Adjustment Address
0E10, 0E11
Note:
The PITCH/YAW data of lens is written only repair parts.
Preparation:
1) Read the PITCH data written on repair parts, and named this
as L
1
.
2) Read the YAW data written on repair parts, and named this as
L
2
.
Fig. 6-1-22
YAW data    
t
 L
2
PITCH/YAW Data
P.PP/ Y
.YY
PITCH data 
t
 L
1
P.PP / Y.YY
9-4. Angular Velocity Sensor Sensitivity Adjustment
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 8, and the fol-
lowing screen will appear.
The buttons on this screen provide the following functions.
[Read] button: Reads and displays the previous data (Dp, Dy)
from the SY-189 board.
[Save] button: Saves the previous data (Dp, Dy) in the PC as a
file.
[Load] button: Loads and displays the previous data (Dp, Dy)
from the file saved in the PC.
• Default file name is as follows:
2) Input the previous data (Dp, Dy) into screen.
If the previous data cannot be read, give a check to the checkbox
at lower left of screen.
3) Input the sensitivity of respective sensors (S
501
, S
502
) read at
“Preparation” into the screen.
If only either sensor was replaced, give a check to the checkbox
for the sensor not replaced at the lower left of the screen.
4) Input the PITCH/YAW data of lens (L
1
, L
2
) read at “Prepara-
tion” into the screen.
If the lens was not replaced, give a check to the checkbox at
the lower left of the screen.
Note:
In order to get the correct value for the adjustment, it is
necessary to input a decimal point (“period” or “com-
ma”) as same format as windows setting because “Nu-
meric Value Format” depend on the language. (F:123
456 789,00, GB:123,456,789.00, D:123.456.789,00)
“Numeric Value Format” setting is available in “Con-
trol Panel” - “Regional and Language Options”.
5) Click the [OK] button, and the adjustment data is then calcu-
lated from the sensor sensitivity value and the calculation re-
sult is written to the memory in the camera.
6) Upon successful completion of the data writing, the following
screen will appear. Check that the steady shot function oper-
ates normally.
DSC-W120_D
p
D
y
DT_xxxxxxxx_yyyymmdd.dat
Date
USB serial number
Data name
Ver. 1.4  2008.08
Page of 39
Display

Click on the first or last page to see other DSC-W120 / DSC-W125 (serv.man3) service manuals if exist.