6-28
DSC-W100_ADJ
3.
LED Check
Page 80
Address 12
Page 8E
Address FE
Using method:
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 40, address: 70, and set data: 01.
3) Select page: 40, address: 98, and check that the data is “00”.
4) Select page: 8E, address: FE, and set data: 20.
5) Select page: 80, address: 12, and set data: 01.
6) Check that all LED are lit.
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 40, address: 70, and set data: 01.
3) Select page: 40, address: 98, and check that the data is “00”.
4) Select page: 8E, address: FE, and set data: 20.
5) Select page: 80, address: 12, and set data: 01.
6) Check that all LED are lit.
•
SELF TIMER/AF ILLUMINATOR
•
AE/AF LOCK
•
FLASH CHARGE
•
MS ACCESS
7) Select page: 80, address: 12, and set data: 00.
8) Select page: 8E, address: FE, and set data: 00.
9) Select page: 00, address: 01, and set data: 00.
10) Click
8) Select page: 8E, address: FE, and set data: 00.
9) Select page: 00, address: 01, and set data: 00.
10) Click
[Disconnect]
on the SEUS screen.
11) Disconnect the USB cable.
12) Turn off the power.
12) Turn off the power.
4.
Switch Check (1)
Page 80
Address 13
Using method:
1) Select page: 80, address: 13.
2) By discriminating the read data, the state of the switches can
1) Select page: 80, address: 13.
2) By discriminating the read data, the state of the switches can
be discriminated.
Function
When data = 00
When data = 01
When data = 02
Shutter button
(XAE LOCK SW)
(XAE LOCK SW)
OFF
ON
ON
RL-064 flexible S002
Shutter button
(XSHUTTER SW)
(XSHUTTER SW)
OFF
OFF
ON
RL-064 flexible S002
Click on the first or last page to see other DSC-W100 (serv.man13) service manuals if exist.