12. CCD Linearity Check
Check that CCD output keeps being straight even ISO sensitivity
is changed.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame)
Measurement Point
Data of page: 10, address: 08 and
09 (2byte data) (Note 2)
Data of page: 10, address: 0A and
0B (2byte data) (Note 2)
Adjustment Page
6F
Adjustment Address
88 to 8F, 9A and 9B
Specified value 1
000 to 300
Specified value 2
000 to 500
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch at the bottom of the set us-
ing a thin and long pin.
Note 2:
2byte data is upper 1byte data and lower 1byte data.
XX XX
Lower 1byte data
(Page: 10, address: 09 or 0B)
Upper 1byte data
(Page: 10, address: 08 or 0A)
Checking method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during camera system
adjustment”
(Refer to page 6-10)
2
Perform “Picture frame
setting”
(Refer to page 6-10)
3
79
F3
[Read]
Note down the data
4
79
F3
66 
[Write]
5
79
EB
[Read]
Note down the data
6
79
EB
FF 
[Write]
7
60
37
25 
[Set]
8
60
01
0F 
[Write]
9
60
02
[Read]
Check the data changes
to “01”.
10
10
08
[Read]
Read the data
(Upper 1byte).
11
10
09
[Read]
Read the data
(Lower 1byte).
12
This 2byte data
(Note 2) is named D1.
13
10
0A
[Read]
Read the data
(Upper 1byte).
14
10
0B
[Read]
Read the data
(Lower 1byte).
15
This 2byte data
(Note 2) is named D2.
16
60
01
00 
[Write]
17
75
9A
[Read]
Note down the data.
18
75
9A
84 
[Write]
Order Page Address
Data
Procedure
19
60
37
23 
[Set]
20
60
01
0F 
[Write]
21
60
02
[Read]
Check the data changes
to “01”.
22
10
08
[Read]
Read the data
(Upper 1byte).
23
10
09
[Read]
Read the data
(Lower 1byte).
24
This 2byte data
(Note 2) is named D3.
25
Calculate S1 using
following equations.
(hexadecimal calcula-
tion)
S1 = D1 –  D3
(S1: absolute value)
26
Check that the S1
satisfies the specified
value 1.
27
10
0A
[Read]
Read the data
(Upper 1byte).
28
10
0B
[Read]
Read the data
(Lower 1byte).
29
This 2byte data
(Note 2) is named D4.
30
Calculate S2 using
following equations.
(hexadecimal calcula-
tion)
S2 = D2 – D4
(S2: absolute value)
31
Check that the S2
satisfies the specified
value 1.
32
60
01
00 
[Write]
33
75
10
[Read]
Note down the data.
34
75
10
FF 
[Write]
35
79
70
[Read]
Note down the data.
36
79
70
53 
[Write]
37
60
37
24 
[Set]
38
60
01
0F 
[Write]
39
60
02
[Read]
Check the data changes
to “01”.
40
10
08
[Read]
Read the data
(Upper 1byte).
41
10
09
[Read]
Read the data
(Lower 1byte).
42
This 2byte data
(Note 2) is named D5.
43
Calculate S3 using
following equations.
(hexadecimal calcula-
tion)
S3 = D1 – D5
(S3: absolute value)
Page of 31