DSC-U20 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 32

Read Sony DSC-U20 (serv.man4) Service Manual online

DSC-U20
6-30
8-2.
White Balance Adjustment (VB)
Mode
PLAY
Signal
Arbitrary
Measurement Point
Data of page: 50, address: 84, 85,
8C and 8D (2byte data) (Note 1)
Adjustment Page
4F
Adjustment Address
87
Specified Value
VB = 112 to 11A
Note 1:
 2byte data is upper 1byte data and lower 1byte data.
XX XX
Lower 1byte data
(Page: 50, address: 85 or 8D)
Upper 1byte data
(Page: 50, address: 84 or 8C)
Adjusting method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during LCD system
adjustment”
(Refer to page 6-22)
2
40
89
02 
[Set]
3
4F
87
80 
[Write]
4
50
90
01 
[Set]
5
50
90
00 
[Set]
6
50
84
[Read]
Read the data
(Upper 1byte).
7
50
85
[Read]
Read the data
(Lower 1byte).
8
This 2byte data (Note
1) is named VB1.
9
50
8C
[Read]
Read the data
(Upper 1byte).
10
50
8D
[Read]
Read the data
(Lower 1byte).
11
This 2byte data (Note
1) is named VB2.
12
Calculate VB using
following equations.
(hexadecimal calcula-
tion)
VB = VB1 – VB2
(VB: absolute value)
13
Check that the VB
satisfies the specified
value. (Note 2)
Note 2:
 When VB does not satisfy the specified value, select page:
4F, address: 87, and write the different data (refer to the
following table), then retry the procedure from 4 to 13.
VB is smaller than the specified value
Decrease the data
VB is larger than the specified value
Increase the data
Processing after Completing Adjustment:
Order Page Address
Data
Procedure
1
40
89
00 
[Set]
2
Release “Data setting
during LCD system
adjustment”
(Refer to page 6-22)
Page of 36
Display

Click on the first or last page to see other DSC-U20 (serv.man4) service manuals if exist.