DSC-U10 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 22

Read Sony DSC-U10 (serv.man4) Service Manual online

DSC-U10
6-20
13. Strobe Adjustment
Adjust the light value and white balance when strobe light flashed.
Mode
CAMERA
Subject
Flash adjustment box (Note 2)
(50 cm from the front of lens)
Measurement Point
Data of page: 6F, address: E8,
EA, EC and EE
Adjustment Page
6F
Adjustment Address
B6, B7 and DB to EF
Specified value
07 to 0F
Note 1:
 Perform this adjustment in the Flash adjustment box.
Note 2:
 Refer to “4. Preparing the Flash adjustment box”. (See
page 6-6)
Note 3:
 “Strobe Adjustment” is available only once after the power
is turned on. If the adjustment is retried, press the RE-
SET switch at the bottom of the set using a thin and long
pin.
Note 4:
 Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch at the bottom of the set us-
ing a thin and long pin.
Adjusting method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during camera system
adjustment”
(Refer to page 6-10)
2
60
2C
01 
[Set]
3
60
92
FF 
[Set]
4
60
93
FF 
[Set]
5
60
01
79 
[Write]
6
60
07
[Read]
Check the data changes
to “01”.
7
60
01
67 
[Write]
Check the flashing.
8
60
02
[Read]
Check the data changes
to “01”.
9
6F
E8
[Read]
Check that the data
satisfied the specified
value.
10
60
01
00 
[Write]
11
60
E1
[Read]
Check the data changes
to “02”.
12
60
01
67 
[Write]
Check the flashing.
13
60
02
[Read]
Check the data changes
to “01”.
14
60
01
00 
[Write]
15
60
E1
[Read]
Check the data changes
to “02”.
16
60
01
67 
[Write]
Check the flashing.
17
60
02
[Read]
Check the data changes
to “01”.
18
60
01
00 
[Write]
19
60
E1
[Read]
Check the data changes
to “02”.
20
60
01
67 
[Write]
Check the flashing.
Order Page Address
Data
Procedure
21
60
02
[Read]
Check the data changes
to “01”.
22
60
01
00 
[Write]
23
60
E1
[Read]
Check the data changes
to “02”.
24
60
01
B9 
[Write]
Check the flashing.
(Note 5)
25
60
02
[Read]
Check the data changes
to “01”.
26
60
01
00 
[Write]
27
60
E1
[Read]
Check the data changes
to “02”.
28
60
01
E7 
[Write]
Check the flashing.
29
60
02
[Read]
Check the data changes
to “01”.
30
60
01
00 
[Write]
31
6F
EA
[Read]
Check that the data
satisfied the specified
value.
32
6F
EC
[Read]
Check that the data
satisfied the specified
value.
33
6F
EE
[Read]
Check that the data
satisfied the specified
value.
Note 5:
The adjustment data will be automatically input to page:
6F, address: B6, B7 and DB to EF.
Processing after Completing Adjustment:
Order Page Address
Data
Procedure
1
60
92
00 
[Set]
2
60
93
00 
[Set]
3
60
2C
00 
[Set]
4
Release “Data setting
during camera system
adjustment”
(Refer to page 6-10)
Page of 35