1-8
– ENGLISH –
5.  Peel the new TP adhesive sheet off the base and attach it to the specified location of the rear cabinet assy.
 
6.  Pass the flexible cable of the LCD assy through the hole in the rear cabinet assy.
 
7.  Attach the LCD assy to the specified location of the rear cabinet assy.
Note:  Match the LCD assy accurately with the specified location and attach it tightly.
 
1-7.  PRECAUTION ON REPLACING THE SY-279 BOARD
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATION DATA WRITE”.
RESTORE DATA
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “RESTORE DATA” to get the data. 
The data getting for this model is as follows.
• USB SERIAL No.
• Angular Velocity Sensor Sensitivity adjustment
• AWB standard data input & check, Color reproduction check
Note: When you cannot read data from the former replace the same time SY-279 board and lens.
Regarding the PMB Portable
PMB Portable has been written in internal memory.
SY-279 board for service is supplied with written the PMB Portable.
USB SERIAL No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Start the Adjust Manual in the Adjust Station and execute the “USB SERIAL No. INPUT”.
Angular Velocity Sensor
When you replace to the repairing board, write down the sensitivity displayed on the angular velocity sensor (SE401).
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity adj”.
SY-279 BOARD (SIDE A)
SE401
PP: PITCH sensor sensitivity
YY: YAW sensor sensitivity
PPP
YYY
Note: The sensor sensitivity of SE401 of SY-279 board is written only repair parts.
1-8.  PRECAUTION ON REPLACING THE 
LENS
When replacing the lens, write down the PITCH/YAW data, FN 
data and wide limit data given on the data sheet of the replacement 
lens for service.
Start the Adjust Manual in the Adjust Station and execute the “Wide 
Limit adj.” and the “Angular velocity sensor sensitivity adj”.
L1/L2
FN
XX
YY
Wide Limit Data (2-byte data)
FN Data
PITCH/YAW Data
FN Data
PITCH data YAW data
XX YY
XX
P.PP/Y.YY
Note: The PITCH/YAW data, FN data and wide limit data of lens are 
written only repair parts.