6-26
DSC-T9_ADJ
11-2. Adjusting method when the lens is replaced
Note down the PITCH/YAW data on the replacement lens for repair.
Adjustment Page
CF
Adjustment Address
0C, 0D
Note 1:
The PITCH/YAW data of lens is written only repair parts.
Preparation:
1) Read the PITCH data written on repair parts, and named this
as L
1
.
2) Read the YAW data written on repair parts, and named this as
L
2
.
Fig. 6-1-50
Adjusting method:
Order Page Address
Data
Procedure
1
00
01
01
Set the data.
2
40
38
00
Set the data.
3
Calculate D
0C
’ and D
0D
using the following equation
(decimal calculation). (Note2)
D
0C
’= (1.00/L
1
×
 134
D
0D
’= (1.00/L
2
×
 134
4
Convert D
0C
’ and D
0D
’ to
hexadecimal notation, and
obtain D
0C
 and D
0D
. (Round
off to one decimal place)
5
CF
0C
D
0C
Set the data.
6
CF
0D
D
0D
Set the data.
7
Save the data.
8
80
34
Check the data is “00”.
9
80
30
Check the data is “00”.
Note 2:
L
1
 and L
2
 are the data read in the “Preparation”.
Note 3:
Refer to “Table 6-2-1. Hexadecimal-decimal Conversion
Table”.
Processing after Completing Initializing:
Order Page Address
Data
Procedure
1
00
01
00
Set the data.
2
Check that the steady
shot operations have
been performed normally.
YAW data    
t
 L
2
PITCH/YAW Data
PITCH data 
t
 L
1
X.XX / X.XX