6-17
DSC-T700_ADJ
6) If the [OK] button is clicked, “3. Auto Orientation Adj.” (Set
the camera to angle 45 degrees clockwise) will be executed.
7) Upon successful completion of “3. Auto Orientation Adj.”  (Set
the camera to angle 45 degrees clockwise)  the following mes-
sage and screen are displayed. Set the camera in accordance
with the message.
8) If the [OK] button is clicked, “3. Auto Orientation Adj.” (Set
the camera to angle 45 degrees counterclockwise) and “4. Re-
lease of Data Setting during Camera Adj.” will be executed.
9) Upon successful completion of all items of the CAMERA
Adjustment 1, the following message is displayed. Click the
[OK] button.
1-6-3.
Adjusting Method
1.
CAMERA Adjustment 1
Note 1:
There is no magnetic substance within around 8 cm of
the camera.
Note 2:
Set the battery pack into the camera.
Note 3:
When CAMERA Adjustment 1 complete, release the
battery pack.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Hall Adj.
3. Auto Orientation Adj.
4. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of CAMERA Adjustment 1.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, the following message and screen are displayed. Set
the camera in accordance with the message.
4) If the [OK] button is clicked, “2. Hall Adj.” will be executed.
5) Upon successful completion of “2. Hall Adj.”, the following
message and screen are displayed. Set the camera in accor-
dance with the message.
Page of 38