DSC-T7 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 24

Read Sony DSC-T7 (serv.man4) Service Manual online

6-22
DSC-T7
1-5-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD Adj. & EVR Data Write
2. COM AC Adj.
3. V-COM Adj.
4. White Balance Adj.
5. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the LCD Adjustment.
2) The Automatic Adjustment Program executes “1. Data Setting
during LCD Adj. & EVR Data Write” and “2. COM AC Adj.”.
3) Upon successful completion of the “2. COM AC Adj.”, the
following message is displayed during execution in “3. V-COM
Adj.”. On the SEUS screen, operate the UP/DOWN key so
that the brightness of portions A and B on the LCD panel is
equal. After the adjustment, click the 
[OK]
 button.
Fig. 6-1-46
4) Upon completion of “3. V-COM Adj.”, “4. White Balance Adj.”
is executed. The following message is displayed, and then check
that LCD screen is not colored.
If colored, change the data of page: 8F, address: 42 and 43 on
the SEUS Operation screen to adjust so that the LCD screen is
not colored.
Fig. 6-1-47
5) If the 
[OK]
 button is clicked, “5. Release of Data Setting dur-
ing LCD Adj.” will be executed.
6) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the 
[OK]
 button.
Fig. 6-1-48
SEUS operation screen
Fig. 6-1-49
Check on the LCD screen (V-COM Adj.)
Fig. 6-1-50
UP/DOWN key
A
B
Page of 31