DSC-T5 (serv.man17) - Sony Digital Camera Service Manual (repair manual). Page 5

Read Sony DSC-T5 (serv.man17) Service Manual online

6-3
DSC-T5_ADJ
Precaution on Replacing the SY-134 board
VIDEO OUT Default Data Check
When you replace to the repairing board, the written data of repairing board also might be changed to original setteing
because of broadcast system (NTSC/PAL).
When the data has changed because of board replaceing etc, check the default data of VIDEO OUT if destination code
is right. If not, rewrite to the right value.
VIDEO OUT Default Data
Page
Address
Data
NTSC
PAL
4F
8D
00
01
4F
A2
00
01
Writing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Select page: 4F, address: 8D, and set data: 00 (NTSC) or data: 01 (PAL).
3) Select page: 4F, address: A2, and set data: 00 (NTSC) or data: 01 (PAL).
4) Select page: 40, address: 38, and set data: 00.
5) Click 
[Save]
 on the SEUS screen.
6) Select page: 80, address: 34, and check that the data is “00”.
7) Select page: 80, address: 30, and check that the data is “00”.
8) Select page: 00, address: 01, and set data: 00.
Initial Language Data Check
If the SY-134 board was replaced, initial language setting may be changed. Accordingly, change the following data so
as to set same initial language as that of the set distributing in each region.
Initial language: Language displayed at the next starting if the setting of Setup menu was reset.
It is different from the language setting selectable with the menu.
Initial Language Data
Page
Address
Data
Language
GP1
GP2
GP3
GP4
4F
8C
00
English
z
z
z
01
Japanese
z
04
Spanish
z
z
06
Portugal
z
08
Simplified Chinese
z
0B
Russian
z
0D
Korean
z
Note:
GP1 is fixed to Japanese.
GP2 is fixed to English.
GP3 is either English, Spanish, or Russian.
GP4 is either English, Spanish, Portugal, Simplified Chinese, or Korean.
Writing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Select page: 4F, address: 8C, and set the Initial Language Data.
3) Select page: 40, address: 38, and set data: 00.
4) Click 
[Save]
 on the SEUS screen.
5) Select page: 80, address: 34, and check that the data is “00”.
6) Select page: 80, address: 30, and check that the data is “00”.
7) Select page: 00, address: 01, and set data: 00.
8) Turn off the camera.
9) Turn on the camera. Execute “Initialize” of Setup screen.
10) Check the language displayed when the camera starts.