Read Sony DSC-T5 (serv.man16) Service Manual online
2-1
2. DESMONTAGEM
DSC-T5_L2
NOTA PARA CONSERTO
• Make sure that the flat cable and flexible board are not cracked of bent at the terminal.
Do not insert the cable insufficiently nor crookedly.
• When remove a connector, dont’ pull at wire of connector. It is possible that a wire is snapped.
• When installing a connector, dont’ press down at wire of connector.
It is possible that a wire is snapped.
• Do not apply excessive load to the gilded flexible board.
Cut and remove the part of gilt
which comes off at the point.
(Be careful or some
pieces of gilt may be left inside)
which comes off at the point.
(Be careful or some
pieces of gilt may be left inside)
DISCHARGING OF THE ST-126 BOARD’S CHARGING CAPACITOR (C005)
The charging capacitor (C005) of the ST-126 board is charged
up to the maximum 300 V potential.
There is a danger of electric shock by this high voltage when the
capacitor is handled by hand. The electric shock is caused by
the charged voltage which is kept without discharging when the
main power of the unit is simply turned off. Therefore, the
remaining voltage must be discharged as described below.
up to the maximum 300 V potential.
There is a danger of electric shock by this high voltage when the
capacitor is handled by hand. The electric shock is caused by
the charged voltage which is kept without discharging when the
main power of the unit is simply turned off. Therefore, the
remaining voltage must be discharged as described below.
Preparing the Short Jig
To preparing the short jig, a small clip is attached to each end of
a resistor of 1 k
a resistor of 1 k
Ω
/1 W (1-215-869-11).
Wrap insulating tape fully around the leads of the resistor to
prevent electrical shock.
prevent electrical shock.
1 k
Ω
/1 W
Wrap insulating tape.
Note: High-voltage cautions
Discharging the Capacitor
Short-circuit between the two points with the
short jig about 10 seconds.
Short-circuit between the two points with the
short jig about 10 seconds.
R:1 k
Ω
/1 W
(Part code:
1-215-869-11)
1-215-869-11)
Click on the first or last page to see other DSC-T5 (serv.man16) service manuals if exist.