DSC-T100 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 37

Read Sony DSC-T100 (serv.man4) Service Manual online

6-35
DSC-T100_ADJ
6-2. SERVICE  MODE
2-1.
APPLICATION  FOR  ADJUSTMENT (SeusEX)
The adjustment software (SeusEX) can change operational coef-
ficients of signal processing, EVR data, etc. same as the adjust-
ment remote commander. The SeusEX performs two-way com-
munication between PC and camcorder using the USB terminal.
The two-way communication result data can be written in the non-
volatile memory.
1.
Connection
1) Connect the HASP key to the USB terminal of the PC.
2) Connect the PC and camcorder with the USB cable.
3) Start the SeusEX on the PC.
4) Click  [Connect] on the SeusEX screen. If the connection is
normal, the SeusEX screen will be as shown in Fig. 6-2-1,
indicating the “connected” state.
Note:
The SeusEX will go in “disconnect” state, if the
camcorder is turned off (for instance, by resetting the
set). In such a case, click [Connect] on the SeusEX
screen to restore the “connected” state.
Fig. 6-2-1
2.
Operation
Block change
To change the block, click [Block] on the SeusEX screen and
enter the block to be changed. The block is displayed in hexa-
decimal notation.
Page change
To change the page, click [Page] on the SeusEX screen and en-
ter the page to be changed. The page is displayed in hexadeci-
mal notation.
Address change
To change the address, click [Address] on the SeusEX screen
and enter the address to be changed. The address is displayed in
hexadecimal notation.
Data change
To change the data, click [Set] on the SeusEX screen and enter
the data. The data is displayed in hexadecimal notation.
This operation does not write the data to the nonvolatile memory.
Data writing
To write the data to the EEPROM, click [Write] on the SeusEX
screen and enter the data value to be written.
To write the data to the flash memory, change the data value
using the [Set] on the SeusEX screen and then click [Save] to
save the data.
Data reading
The data displayed on the SeusEX screen are the data values at
the time when the pages and addresses were set, and they are
not updated automatically. To check the data change, click [Read]
on the SeusEX screen and update the displayed data.
Page of 44
Display

Click on the first or last page to see other DSC-T100 (serv.man4) service manuals if exist.