DSC-T10 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 23

Read Sony DSC-T10 (serv.man4) Service Manual online

6-21
DSC-T10_ADJ
6.
CAMERA Adjustment 4
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. F No. Compensation
4. Measure Gain Adj.
5. Mechanical Shutter Adj.
6. Light Value Adj.
7. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 4.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-29 to
Fig. 6-1-31, set the subject and click the [OK] button.
Fig. 6-1-32
After that, the next message is displayed. Then, change the chart
in accordance with the message.
Fig. 6-1-33
4) Click the [OK] button, and the items from “3. F No. Compen-
sation” to “7. Release of Data Setting during Camera Adj.”
will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 4, the following message is displayed. Click the
[OK] button.
Fig. 6-1-34
5.
Picture Frame Setting (Standard Picture Frame)
In the “CAMERA Adjustment 4”, “AWB 3200K-5800K Standard
Data Input” and “CAMERA Adjustment 5”, set the picture frame
so as to attain the positions shown in the following figure when
shooting the 9 colors chart.
Check on the oscilloscope
Measurement Point: Video terminal of USB, A/V, DC IN cable for
multi-use terminal (75
Ω terminated)
1. Horizontal period
Fig. 6-1-29
2. Vertical period
Fig. 6-1-30
Check on the monitor TV or the LCD screen
Fig. 6-1-31
A
A
B
A = B
V
B
C
C
C =
B
3
Transparent window
Effective picture frame
A
A
B
Blue
C14
Magenta
White
Cyan
Red
Yellow
Green
W14
C
C
B
C =
A = B
C14: Filter for AWB 5800K adjustment
A
2
B
3
Page of 37