DSC-T10 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 5

Read Sony DSC-T10 (serv.man2) Service Manual online

1-1
DSC-T10_L2
1. SERVICE NOTE
Self-diagnosis display
• C: ss: ss
You can reverse the camera
malfunction yourself. (However,
contact your Sony dealer or local
authorized Sony service facility
when you cannot recover from the
camera malfunction.)
• E: ss: ss
Contact your Sony dealer or local
authorized Sony service facility.
Display Code
  C:32:ss
  C:13:ss
Countermeasure
Turn the power off and on again.
Format the “Memory Stick” or internal
memory.
Cause
Trouble with hardware.
“Memory Stick” or internal memory is
unformatted.
Caution Display During Error
SYSTEM ERROR
FORMAT ERROR
MEMORY STICK ERROR
  E:61:ss
  E:91:ss
1-1. DESCRIPTION ON SELF-DIAGNOSIS DISPLAY
Insert a new “Memory Stick”.
“Memory Stick” is broken.
Turn the power off and on again.
Trouble with internal memory.
INTERNAL MEMORY ERROR
Checking of lens drive circuit.
When failed in the focus and zoom
initialization.
Checking of flash unit or replacement
of flash unit. (Note)
Abnormality when flash is being
charged.
Note:
After repair, be sure to perform “1-2. PROCESS AFTER FIXING FLASH ERROR”.
1-2. PROCESS AFTER FIXING FLASH ERROR
When “FLASH error”  (Self-diagnosis Code  E : 91 : ** ) occurs, to prevent any abnormal situation caused by high voltage, setting of the
flash is changed automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Flash error code can be initialized by the operations on the Setup screen.
Method for Initializing the Flash Error Code
  E:62:ss
Steady shot function does not work well.
Inspect angular velocity sensor
Peripheral circuits.
Initializes the setting to the default setting.
1
Select [OK] with v on the control button, then press z.
The message “Initialize all settings Ready?” appears.
2
Select [OK] with v, then press z.
The settings are reset to the default setting.
To cancel the resetting
Select [Cancel] in step 1 or 2, then press z.
• Make sure that the power is not disconnected during resetting.