DSC-S80 (serv.man3) - Sony Digital Camera Service Manual (repair manual). Page 27

Read Sony DSC-S80 (serv.man3) Service Manual online

6-25
DSC-S80
1-7.
INITIALIZATION OF DATA
[LCD TYPE  CHECK]
Model
DSC-S60/S80/ST80
DSC-S90
LCD type
TYPE C
TYPE C or TYPE S
Checking Method:
1)Select page: 80, address: 7E.
2)By discriminating the read data, the type of LCD can be
discriminated.
Data
LCD type
0C to 21
TYPE S
8A to A7
TYPE C
1.
Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
Note:
If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “04: TYPE C” or “05: TYPE S”.
4) Click 
[All]
  of the ALL SELECT buttons to select all pages.
(Fig. 6-1-57 A)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) Click 
[Save]
 on the SEUS screen.
9) Wait for more than 3 sec.
10) Select page: 80, address: 30, and check that the data is “00”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click 
[Con-
nect]
 on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the
power button.)
2.
Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
Note 1:
If the 6D or 6E or 6F or 78 or 79 page data have been
initialized, the following adjustment needs to be per-
formed again.
1) Camera system adjustments
Note 2:
If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “04: TYPE C” or “05: TYPE S”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-57
B
)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) Click 
[Save]
 on the SEUS screen.
9) Wait for more than 3 sec.
10) Select page: 80, address: 30, and check that the data is “00”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click 
[Con-
nect]
 on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the
power button.)
Fig. 6-1-57
B
A
04
04: TYPE C
05: TYPE S
Page of 31
Display