DSC-S60, DSC-S80, DSC-S90, DSC-ST80 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 51

Read Sony DSC-S60 / DSC-S80 / DSC-S90 / DSC-ST80 (serv.man2) Service Manual online

— 2 —
DSC-S60/S80/S90/ST80_L2
2-5. ZOOM  MOTOR  UNIT  REPLACEMENT  AND  INSPECTION  PROCEDURES
Service parts
Part Number
Part Name
Quantity
1
2-891-376-01
MOTOR UINT, ZOOM
1
Note:
These parts are not prepared as service parts.
Recycle removed screws.
1
Remove solder of “Zoom motor terminal” (4 point).
* Be careful for terminal deformation and breaking of coil.
2
Remove two screws that fix “Motor Unit, Zoom”.
* Removed screws are recycled. Do not lose them.
* Lens barrel should not be pulled out.
* Do not touch the motor directly for preventing rust. (Use finger cot etc...)
* Be careful not to damage the appearance.
3
Confirming Zoom function manually.
3-1. Turn Lens gear to clockwise and poke put the lens barrel until the position of open lens barrier.
3-2. Turn to the lens barrel (outside) for TELE end and WIDE end for four or five times and then confirm no against force during stroke.
3-3. During the lens barrel stroke check, confirm the condition of lens gear if there is no deformation of damage.
3-4. If everything is OK, step forward to next.
* If found any problem until this point, it is impossible to repair ZOOM motor unit. Therefore, replace the lens block assembly.
2. DISASSEMBLY
1
not supplied (Note)
Zoom Motor Unit
Two Screws
Solder
Rotate lens barrel and stroke
Length of gear
All circumferences
Page of 57
Display