DSC-S5000 - Sony Digital Camera Service Manual (repair manual). Page 13

Read Sony DSC-S5000 Service Manual online

DSC-S5000
3-5
 
1. Disconnect the soldered connection.
2. Remove the four screws.  
3. Remove the four screws.   
3-2.  Replacing MOTOR UNIT
Rear retainer 
 
Rear lens spring 
2ND FOCUS GEAR
 
PI part 
4. Remove the rear retainer with careful attention so as not to let the rear lens spring fly away.
5. Remove the 2ND FOCUS GEAR.
6. Remove the PI part with a tool such as flat-blade screwdriver.  
Page of 27