Wrap insulating tape.
NOTE  FOR  REPAIR
•  Make sure that the flat cable and flexible board are not cracked of
bent at the terminal.
 Do not insert the cable insufficiently nor crookedly.
•  When remove a connector, do not pull at wire of connector. It is
possible that a wire is snapped.
•  When installing a connector, do not press down at wire of connector.
 It is possible that a wire is snapped.
•  Do not apply excessive load to the gilded flexible board.
The charging capacitor is charged up to the maximum 310 V
potential.
There  is  a  danger  of  electric  shock  by  this  high  voltage 
when the capacitor is handled by hand.  The electric shock 
is caused by the charged voltage which is kept without dis-
charging when the main power of the unit is simply turned 
off.  Therefore, the remaining voltage must be discharged as 
described below.
Preparing the Short Jig
To preparing the short jig, a small clip is attached to each end 
of a resistor of 1 kΩ /1 W (1-215-869-11).
Wrap insulating tape fully around the leads of the resistor to 
prevent electrical shock.
DISCHARGING OF THE CHARGING CAPACITOR
Cut and remove the part of gilt
which comes off at the point.
(Be careful of that some
pieces of gilt may be left inside)
Note:
Note:
High-voltage cautions
High-voltage cautions
Discharging the Capacitor
Short-circuit from the outside of
the condenser poles with the short jig
about 10 seconds.
To avoid the spark with the metal plate,
wrap the short jig with the insulation tape.
Short-circuit from the outside of
the condenser poles with the short jig
about 10 seconds.
To avoid the spark with the metal plate,
wrap the short jig with the insulation tape.
R:1 kΩ/1 W
(Part code: 1-215-869-11)